BACTERIOLOGICAL AND PHYSICOCHEMICAL, EVALUATION OF DRINKING WATER POTENTIAL FROM BOREHOLES AND WELLS AT INDUSTRIAL AND SEWAGE DISPOSAL SITES OF KANO METROPOLIS
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Department of Microbiology, Nasarawa State University Keffi
DOI
Abstract
This work has evaluated borehole and Well waters located within the industrial and sewage
disposal areas of Bompai, Sharada, Chalawa, Gyadigyadi(court road) and Wailari, with a view to
determine their bacteriological and physicochemical qualities. A total of Three hundred and fifty
(350) samples, seventy (70) boreholes and seventy (70) wells (from each location) were sampled
and analyzed for their mean Viable counts, coli form, faecal coliform counts, Staphylococcal
count, and salmonella-shigella count using standard microbiological techniques respectively. The
physicochemical parameters monitored included pH, electrical conductivity, Total Dissolved
Solid, Dissolved Oxygen, Biological Oxygen Demand, Turbidity, chloride, nitrate, phosphate,
zinc, iron, lead, manganese and chromium. The mean viable counts, coliform and faecal coliform
counts in the well samples from industrial sites were shown to be 2.83, 2.41, 2.39, 1.50 and 2.88
x 104 cfu/ml, respectively, These were higher than the counts recorded in borehole waters with
mean values of 1.61,1.40,1.50,1.31 and 1.00 x 103 cfu/ml respectively while that of sewage
disposal site wells showed the mean of 3.05, 2.35, 3.12, 1.5 and2.80 cfu/ml whereas the
boreholes showed 2.85, 2.75, 2.31, 1.45, and 1.52 du/ml. Bacterial count was not observed in
the control boreholes (non- industrial area) with a very few count 1.0 x 101 cfu/ml in the well
from same location, Hence, the well samples from sewage disposal sites was shown to be
significantly contaminated (P=0.01 1) than water samples from the other locations. Cultural,
morphological and biochemical characterization of bacterial genera isolated include E coli.
Pseudomonas sp Shigella sp., Proteus sp., Klebsiella sp., Staphylococcus sp. Salmonella sp. and
Enterobacter sp. However seasonal means is much higher during dry season than in rainy season
which may be due to increase water level in the rainy season, the wells showed elevated mean
value of lead (0.14mg/I), EC (590.9 us/cm), TDS (119.13mg/l), DO (4.67mg/I), BOD (1.25mg/l),
Zinc (1.76mg/I), iron (0.6mg/l), Manganese (0.44mg/I) and Chromium (0.57mg/l) when
compared to the borehole samples with mean average value of lead(0.01mg/I), EC (483.75),
TDS (54.01mg/I), DO (4.12mg/l), BOD(l .2mg/I), Zinc (0.91mg/l), Iron (0.16mg/I), Manganese
(0.29mg/l) and Chromium (0.05mg/l).The most frequent occurring bacteria on subjection to
molecular identification showed E coli. Pseudomonas Shigella Proteus Klebsiella
Staphylococcus Salmonella and Enterobacter. The result showed that some of the borehole and
well samples are not within the recommended limit of WHO (2006) and NSDWQ (2007)
standard for drinking water. The borehole and well water should therefore be protected and
treated before consumption.
Description
Keywords
Citation
Abdullahi, A.S. (2021) BACTERIOLOGICAL AND PHYSICOCHEMICAL, EVALUATION OF DRINKING WATER POTENTIAL FROM BOREHOLES AND WELLS AT INDUSTRIAL AND SEWAGE DISPOSAL SITES OF KANO METROPOLIS