ELECTRICAL RESISTIVITY SURVEY OF FAILED PATH ALONG ABUJA KEFFI - AKWANGA HIGHWAY
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Department of Physics, Nasarawa State University Keffi
DOI
Abstract
Geophysical investigation of failed parts on Abuja-Keffi-Akwanga expressway, Nasarawa
State, Nigeria, was carried out using Electrical Resistivity Survey Techniques to ascertain the
contribution of the subsurface geological structure on which the road was laid to the road
failure. The objectives of this study were to determine the depth to the bedrock, delineate
failed and stable portions of the road pavement, and determine the composition of the earth
materials, their thickness and resistivity. At the field electrodes were arrayed linearly and
parallel to the pavement, applying Schlumberger Configuration. The current electrodes
distance was varied from lm to 100m and potential electrodes varied from 0.3 to 5m, with
current and potential electrodes maximum distances, 100m and 5m respectively. A Total of
50 Vertical Electrical Sounding (VES) stations were established spreading along stable and
unstable sections of the road. The data collected was analysed using Win-Reist Software, to
determine the curve types and the number of layers, and Rock-Works software to produce the
geoelectric sections. The result of the analysis revealed that there were three (3), Four (4) and
Five (5) geolectric sections (layers) for both the Stable and Unstable sections of the road.
From the Stable portions of the road, there were varied number of layers or lithology, three
(3), Four (4) and five (5) geoelectric sections or layers were delineated at different VES
Stations along the Expressway with depth to the bedrock ranging between I.5m-22.2m for
the three (3), 6.4m - 28.3m for the Four (4) and 6.0m - 26.1m for the Five (5). The geoelectric
section of the stable portions of the Highway revealed that eleven (11) VES points have their
second layer supporting the first layer to be made up of moderately competent lithology to
highly competent lithology (Lateritic Soil, Lateritic Clay and Laterite), and nine (9) VES
points shown incompetent lithology (Clayey Soil). The stable segments of the road pavement
revealed comparative higher resistivity in both first layers and the second layers. Also, from
the unstable portion of the road, three (3), Four (4) and five (5) geoelectric sections were
delineated at different VES Stations along the Expressway with depth to the bedrock ranging
between 1.9m - 15.9m for VES points that have three (3) layers, 5.5m - 32.9m for VES points
that have Four (4) layers and only VES 34 with Five layers has a depth of 35.7m. the
geoelectric sections of the Ustable Portions of the pavement shown that twenty-four (24)
VES points have their Second layers made up of incompetent Lithology (Clayey soil), while
only three (3) VES points are composed of Moderately competent to Highly competent
lithology (Laterite Clay, Lateritic Soil and Laterite). The failed segments or unstable
pavement of the Abuja-Akwanga road, probed points along the road comprised of thin topsoil
which has high clay content and second layers reach in clay materials having resistivity as
low as 8£2m as explained in the geoelectric sections.
Description
Keywords
Citation
Lucky, I. (2014) ELECTRICAL RESISTIVITY SURVEY OF FAILED PATH ALONG ABUJA KEFFI - AKWANGA HIGHWAY