This study focused on Determination of pathogenicity of coliform bacteria isolated from well
water used in Karu Nasarawara State. Nigeria. Twenty (20) well water samples were
collected from different areas in Karu. Presumptive test method was to determine the
coliform bacteria load. Isolation and identification of bacteria from the samples collected was
carried out using standard microbiological methods. Pathogenicity such as Survival in
Hydrogen peroxide and survival in blood serum was carried out using standard
microbiological techniques. Total coliform counts from selected well water in Ado ranged
from 9 MPN/ 100ml to 26 MPN / 100ml. New Nyanya (4 MPN/ 100ml - 34 26 MPN
100ml). Area I village (8 MPN/ 100ml to 420 MPN/ 100ml). Massaka (11 MPN/ 100ml to
170 MPN/ 100ml). The bacteria isolated were E. coli. Klebsiella species, Enierohacier
species and Salmonella Specie. The highest coliform bacteria isolated from Ado was E col:
(60.0 %) and the lowest was Enierobacter sp (20.0 %). From New Nyanya the highest was
Salmonella spp and Citrobacter sp (80.0 %). From Area 1 village the highest coliform
bacteria isolated was E coli and Klebsiella spp (80.0 %) and lowest was Citrobacter sp (60.0
%). From Massaka the highest coliform bacteria isolated was Enierobacter sp and and the
lowest was Salmonella spp and Citrobacter sp (40.0 %). The highest coliform bacteria that
survived in hydrogen peroxide from Ado was Salmonella spp. Enierobacter sp, Klebsiella
spp (100 %) the lowest was E. coli (33.3 %). From New Nyanya the highest survival
observed was from Enierobacter sp and Citrobacter sp (100%) and the lowest was E. coli
(50.0 %). From Area 1 village the highest survival recorded was Salmonella spp (100%) and
the lowest was Enierobacter sp (33.3 %). From Masaka the highest survival observed was
from Klebsiella spp and Citrobacter sp (100%) and low'est was Enierobacter sp (25.0 %).
The highest bacteria survival in blood serum recorded From Ado was Salmonella sp and
Klebsiella sp (50.0 %) and lowest was E. coli (33.3%). From New Nyanya the highest
recorded was E. coli (100 %) and lowest was Citrobacter sp (25.0 %). From Area 1 village
the highest observed was E. coli (75.0 %) and the lowest was Klebsiella spp (25.0 %). From
Massaka the highest bacteria survived in serum observed was Citrobacter sp (100 %) and the
lowest was Enierobacter sp (25.0 %). The high occurrence of coliform bacteria in well water
in the study area makes the wellwater unfit for human use. well water use in Karu should be
boiled before use because it is contaminated with pathogenic coliform bacteria.