Geophysical Engineering Investigation AroundMakiyaye Village, Shika Area Within The Basement Complex Of North-Western Nigeria
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Department of Geology and Mining, Nasarawa State University Keffi
DOI
Abstract
Geophysical investigation for engineering studies
was carried out around Makiyaye village which
falls within the Basement Complex of North-
Western Nigeria. The study is aimed at
evaluating the competence of the near surface
formation as foundation materials, and to
unravel the subsurface profile which in turn
determines if there would be any subsurface
lithological variation(s) that might lead to
structural failure at the site and evaluating the
groundwater potential of the site and
determining the level of safety of the
hydrogeologic system. Vertical Electrical
Sounding (VES) using Schlumberger array was
carried out at eighteen (18) VES stations. ABEM
terrameter (SAS 300) was used for the data
acquisition. The field data obtained have been
analysed using computer software (IPI2win)
which gives an automatic interpretation of the
apparent resistivity. The geoelectric section
revealed three to four lithologic units defined by
the topsoil, which comprises clayey-sandy and
sandy lateritic hard pan; the weathered
basement; partly weathered/fractured basement
and the fresh basement. The resistivity values
range from 28 - 354Ωm in the topsoil, 70 -
356Ωm in the weathered basement, 245 - 694Ωm
in the fractured basement and 1114 - 3699Ωm in
the fresh basement . Layer thicknesses vary from
0.38 – 2.64m in the topsoil, 0.7 – 37.36m in the
weathered layer, 5.86 – 34.2m in the fractured
basement. Depth from the surface to
bedrock/fresh basement generally varied
between 2.64 and 44.11m. Based on the resistivity
values, it is concluded that the subsurface
material up to the depth greater than 20m is
competent and has high load-bearing capacity.
However, resistivity values less than 100Ωm at
depths of 10 - 15m indicate high porosity, high
clayey sand content and high degree of saturation
which are indications of soil conditions requiring
serious consideration in the design of massive
engineering structures. The hydrogeologic system
at the site is vulnerable to contamination. Hence,
the result reasonably provide a basis for which
groundwater potential zones are appraised for
safety in case potential sources of groundwater
contamination sites such as septic tanks and sewage channels are planned
for the area under study.
Description
Citation
1. Ariyo, S.O. and Oguntade, A.K. (2009). Geophysical Investigation for Groundwater Potential in Mamu Area, Southwestern Nigeria. Medwell Online Journal of Earth Sciences, Vol.3, no.1, pp.10-13. 2. Ariyo, S.O. and Osinawo, O.O. (2007). Hydrogeophysical Evaluation of Groundwater Potentials of Atan/Odosenbora. Vol.9, no.1, pp. 50-65. 3. Bala, A.E. and Ike, E.C. (2001). The Aquifer of the Crystalline Basement Complex Area of Africa. Quarterly Journal of Engineering Geology, Vol.18, pp. 35-36.Burger, R.H (1992), ‘Exploration Geophysics of the Shallow Subsurface’. prentice Hall, U.S.A. pp. 30- 56 4. Blyth, F.G.H and de Freitas, M.D., (1988).A Geology for Engineers’, Butler and Tannar Ltd, Frome and London. Pp. 292-293. 5. Geology for Engineers. Butler and Tannar Ltd, Frome and London. Pp. 292-293. 6. Burland, J.B and Burbidge, M.C (1981). Settlement of Foundations on Sand and Gravel Proceedings of the Institution of Civil Engineers, 78(1), pp. 1325- 1381. 7. Goh, C.L., and Adeleke, B.O., (1978). Certificate Physical and Human Geography’ Oxford University Press, Ibadan,pp78-150.