Geological traversing at Nasarawa State University Keffi, part of Keffi Sheet
208NE, North-central Nigeria, revealed that the area is underlain by the Basement
Complex rocks consisting of biotite gneiss, granitic gneiss and schist. The
structural trends are mostly in NNW-SSE and NE-SW directions and foliation in
the NE-SW direction. Surface geophysical investigation was conducted using the
new hybrid Wenner-Schlumberger array, where fifty (50) stations were
investigated along seven established profiles to determine the groundwater
potential of the area. Six curve types were observed; HA, KA, QH, HAK and KHA;
QHA-types has the highest frequency of occurrence while KA and HAK-types has
the least. Results revealed that the top soil being the 1st layer with resistivity (62-
5800 Ωm) and thickness (1-2 m). Laterite is the 2nd layer with resistivity (20-5550
Ωm), and thickness (2-7 m). The weathered basement is the 3rd layer with
resistivity (43-2080 Ωm) and thickness (5-20 m). The fractured basement is the
4thlayer in the five (5) geoelectric layer case with resistivity (115-1700 Ωm) and
thickness (25-50 m); while the partially weathered/fractured basement forms the
4thlayer in the six (6) geoelectric layer case with resistivity (66-2059 Ωm) and
thickness (10-30 m). The fresh basement forms the 5thlayer in the five (5)
geoelectric layer case with resistivity (312-2170 Ωm), while the fractured
basement forms the 5thlayer in the six (6) geoelectric layer case with resistivity
(139-2800 Ωm), and thickness (10-50 m). The fresh basement forms the 6thlayer
in the six (6) geoelectric layer case with resistivity (310-3800 Ωm). The depth to
fresh basement or overburden thickness range from 29-79.5 m, which implies that
the area is generally good for groundwater development, especially places with
distinctive weathered and/or fractured layers thicknesses. Groundwater potentials
were zoned into low, medium and high potentials for groundwater development.
Wenner data extracted and interpreted have a good degree of correlation with the
Schlumberger results, the structural trends observed on the geological structures
and with existing geology