ASSESSMENT OF RADIATION DOSE IN COMPUTED TOMOGRAPHY EXAMINATION OF ADULT PATIENT IN ABUJA AND KEFFI HOSPITALS IN NIGERIA

dc.contributor.authorKambari, Ladan Sabiu
dc.date.accessioned2023-12-14T07:55:58Z
dc.date.available2023-12-14T07:55:58Z
dc.date.issued2017-09-07
dc.description.abstractAssessment of Radiation dose in computed tomography examination of Adult patient in Abuja and Keffi, Hospitals in Nigerian was carried out. The three study centers are, National hospital Abuja, Garki hospital and federal Medical Centre Keffi, Nasarawa State. CT scan is considered to be the first investigative modality of choice for patient with severe head, chest and abdominal injuries. For us to achieve this, professionals must adhere to the principles of justification of practice and optimization of radiation protection. Dose report and scan parameters for head, chest and abdomen were assessed during seven months period at the three study centres. Ethical approval were obtained from the study centers. Data on CT Dose index (CTDIw) and dose length product (DLP) available and achieved on CT scanner control console was recorded for a minimum of 10 average sized patients for each facility to established a local Diagnostic reference level (LDRLs) and radiation dose optimization Data were collected, using a purposive sampling technique, from 131 adult patients weighing 70±3kg) from Philip brilliance, Toshiba Alexion and General Electric (GE) CT scanners for the study. The collected data were analyzed using SPPSS version (20) statistical software. Third quartile values of the estimated LDRLs for CTDIw and DLP were determined as (49.8mGy and 9639mGy) and (10.9mGy and 432.8mCy*cm) and (12.7mGy and 560mGy*cm) for head, chest and abdominal CT scan, respectively. This study has established local diagnostic reference levels (LDRLs). And the CTDIw obtained are almost relatively higher to the reported data from the European Commission (Head: 10mGy, Chest: 10mGy and Abdomen 12.7mGy). The DLP are comparably lower than all the reported value from the European commission (Head:1000mGy, Chest:600mGy and Abdomen: 800mGy). CT dose optimization is recommended.en_US
dc.identifier.urihttps://keffi.nsuk.edu.ng/handle/20.500.14448/6071
dc.language.isoenen_US
dc.publisherA DISSERTATION SUBMITTED TO THE SCHOOL OF POSTGRADUATE STUDIES, DEPARTMENT OF PHYSICS, FACULTY OF NATURAL AND APPLIED SCIENCES IN PARTIAL FULFILLMENT OF THE REQUIREMENT FOR THE AWARD OF MASTER DEGREE IN RADIATION AND MEDICAL PHYSICS OF NASARAWA STATE UNIVERSITY, KEFFIen_US
dc.titleASSESSMENT OF RADIATION DOSE IN COMPUTED TOMOGRAPHY EXAMINATION OF ADULT PATIENT IN ABUJA AND KEFFI HOSPITALS IN NIGERIAen_US
dc.typeThesisen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ASSESSMENT OF RADIATION DOSE IN COMPUTED TOMOGRAPHY EXAMINATION OF ADULT PATIENT IN ABUJA AND KEFFI HOSPITALS IN NIGERIA.pdf
Size:
2.15 MB
Format:
Adobe Portable Document Format
Description:
Dissertation
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description: