MICROBIOLOGICAL AND PHYSICOCHEMICAL EVALUATION OF EFFLUENT FROM THREE BEVERAGE INDUSTRIES IN ABUJA NIGERIA
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Department of Microbiology, Nasarawa State University Keffi
DOI
Abstract
The beverage industry has some unique challenges in the discharge of its effluent as the effluent
may contain pollutants that can contaminate the environment especially water bodies, leading to
agricultural loss and potential hazards to aquatic and human lives. This study aimed at evaluating
microbiological, physicochemical and heavy metal concentrations of effluent from three
beverage (soft drink, juice and yoghurt) manufacturing industries in Abuja Nigeria. Standard
microbiological methods were used in isolation and identification of bacteria and fungi. The total
heterotrophic bacteria count was highest 19.03 cfu/ml at point D (20 meters away from point of
discharge) and lowest 12.66 cfu/ml at point F (mixing point of effluent with stream) from
industry A. From industry B, the highest total heterotrophic bacteria count was from point V
(point of discharge) 15.66 cfu/ml and lowest was from point U (20 meters away from point of
discharge) 10.10 cfu/ml. The highest bacteria isolated from industry A were Pseudomonas spp
(25.0%) and the lowest was Klebsiella spp (8.3 %). From Industry B the highest bacteria isolated
were Staphylococcus spp (33.3 %) and the low.est were Pseudomonas spp and Bacillus sppl
(16.0 %). From Industry C the highest bacteria isolated was Bacillus spp (58.3 %) and
Corynbacteria spp was the lowest (25,0%). The fungi isolated from Industry A were
Saccharomyces cerevisiae (50.0 %) and Aspergillus niger (16.6 %). From Industry B the highest
fungi isolated were Saccharomyces cerevisiae' (41.6 %) and lowest was Fusarium redolen (16.6
%). From industry C fungi isolated were Saccharomyces cerevisiae (41.6 %) and Aspergillus
niger (50.0%). For the physicochemical parameters of the industries, the hydrogen ions (pH)
concentration ranged from 3.160 -7.5, temperature ranged from 28- 36°C, TDS ranged from
250.17 - 749.77 ppm, TS ranged from 110.00 - 751.00 mgL’1, TSS ranged from 0.190 - 4.25
mgL'1, Turbidity ranged from 32.6 -551.7 NTU, BOD ranged from 2.14 -180.6 mgL’1 and COD
ranged from 16.4 - 110.5 mgL’1. There is need to treat effluent from these industries before
discharging into environments
Description
Keywords
Citation
Ezeuogo, C.G. (2024) MICROBIOLOGICAL AND PHYSICOCHEMICAL EVALUATION OF EFFLUENT FROM THREE BEVERAGE INDUSTRIES IN ABUJA NIGERIA