SURVEY OF MAMMOGRAPHY RADIATION DOSES TO ESTABLISH LOCAL DIAGNOSTIC REFERENCE LEVEL IN ABUJA MUNICIPAL AREA COUNCIL, FEDERAL CAPITAL TERRITORY, NIGERIA

dc.contributor.authorEje, Ngozi Adaora.
dc.date.accessioned2021-04-22T10:48:44Z
dc.date.available2021-04-22T10:48:44Z
dc.date.issued2018-10-15
dc.descriptionDissertationen_US
dc.description.abstractDiagnostic Reference Levels (DRLs) are optimization tools used in radio-diagnostic procedures. Radiation doses used in most radio diagnostic procedures are associated with a potential risk of radiation induced cancers. It is therefore important to continually seek measures to reduce radiation doses in such diagnostic procedures to the minimum. The purposes of this study were to survey and compare mammography doses in some hospitals within Abuja Municipal Area Council (AMAC) with a view to establishing a local DRL; to compare the Local DRL obtained with those in literature and to ascertain whether there is a variation of radiation doses between mammograms for the same procedure. A total number of 47 female patients were included. Four mammography centres participated. Only one centre was using Automatic Exposure Control (AEC). The mean doses in milliGray (mGy) for the Craniocaudal (CC) projection were 4.03, 2.03, 2.54 and 1.18 and for the Mediolateral Oblique (MLO) projection was 2.73, 2.16, 1.88 and 2.19 for centres A, B, C and D respectively. The total mean dose per breast from both projections was 6.76, 4.19, 4.41 and 3.38 mGy for centres A, B, C and D respectively. The results of this study were within the acceptable limits specified by International Atomic Energy Agency (IAEA HHS No2, 2009).The minimum mean glandular dose was found between the digital system which was operated under Automatic Exposure Control (AEC) and one of the manually selected exposure factor systems. This highlights the need for optimization of radiation practice in the other manually selected systems. ALARA (As low As Reasonably Achievable) principle could be achieved in these centres by adjusting the exposure factors according to the breast thickness while maintaining image quality. The DRL suggested for AMAC is 2.45mGy for CC and 2.24mGy for MLO. Kilovolts and the tube current time products should be selected correctly according to the breast thicknessen_US
dc.identifier.citationA DISSERTATION SUBMITTED TO THE SCHOOL OF POSTGRADUATE STUDIES, NASARAWA STATE UNIVERSITY KEFFI, IN PARTIAL FULFILMENT OF THE REQUIREMENTS FOR THE AWARD OF MASTER OF SCIENCE DEGREE IN RADIATION AND MEDICAL PHYSICSen_US
dc.identifier.urihttp://localhost:8080/xmlui/handle/123456789/1170
dc.language.isoenen_US
dc.titleSURVEY OF MAMMOGRAPHY RADIATION DOSES TO ESTABLISH LOCAL DIAGNOSTIC REFERENCE LEVEL IN ABUJA MUNICIPAL AREA COUNCIL, FEDERAL CAPITAL TERRITORY, NIGERIAen_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
SURVEY OF MAMMOGRAPHY RADIATION DOSES TO ESTABLISH LOCAL DIAGNOSTIC REFERENCE LEVEL IN ABUJA MUNICIPAL.pdf
Size:
1.23 MB
Format:
Adobe Portable Document Format
Description:
Thesis and Dissertations

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: