assessment of ambient temperature of housing types in keffi TOWNSHIP, NASARAWA STATE, NIGERIA
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Geography Department, Nasarawa State University Keffi
DOI
Abstract
Indoor temperature affects thermal comfort and human health. In a changing climate with
a predicted change in temperature extremes\ understanding indoor temperatures, both hot
and cold, of different housing types is imperative. This study assessed indoor temperatures
of housing types in Keffi Township using a survey research design. The aim of the study
was to investigate indoor temperature differential in different housing types in Nasarawa
State, Nigeria. To achieve this aim, data on housing types and building material types as
well as morning, afternoon and evening indoor temperatures were acquired through
measurements and observation using handheld Mercury Thermometer and field note. The
acquired data were analysed using both descriptive and inferential statistical tools and the
results presented in tables. Findings showed that apartment block, tenement/multi-tenented
traditional and detached/semi-detached were the four housing types in the study
area with detached/semi-detached being the dominant (31.1%) type. Zinc (64%), ceiling
board (74.49%) cement wall (84%) and cement floor (52%) were the most commonly used
materials for roofing, ceiling, walling and flooring of the different housing types in the
study area. The morning (26.7 °C), afternoon (28.3 °C) and night (27.6 °C) indoor
temperatures of the tenement/multi-tenanted housing type was the highest while those of
traditional housing were the lowest. The afternoon and night indoor temperatures varied
significantly and the main determinants of the variation were found to be differences in
roofing and ceiling materials. Zinc roof, no ceiling, cement wall and floors were the main
contributors to increasing indoor afternoon temperature while step-tiles roof, POP
ceiling, brick walls and mud floor had the highest relative decreasing effect. Zinc roof,
board ceiling, cement wall and floor contributed majorly to increasing indoor night
temperature. Apart from the addition of no-ceiling, all other materials that contributed
majorly to decreasing indoor afternoon temperature were same for indoor night
temperatures. The study concluded that indoor temperatures are affected by housing types
and construction materials in the study area and apart from zinc roof; no-ceiling, cases
and board ceiling; cement walls, all other roofing, ceiling, walling and flooring materials
guarantees a much conducive indoor temperatures. Hence, it was concluded that,
authorities concern with housing development in the Keffi LGA should ensure that
upcoming Tenement/multi-tenanted houses are constructed with relatively affordable
materials that guarantees comfortable indoor afternoon and night temperature such as the
use of PVC roofs and Aluminium roofing sheet
Description
Keywords
Citation
A DISSERTATION SUBMITTED TO THE SCHOOL OF POSTGRADUATES STUDIES, NASARAWA STATE UNIVERSITY, KEFFI IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE AWARD OF MASTER OF SCIENCE IN GEOGRAPHY